ALUMINUM (gas)

  Unit Function Accuracy/ Linearity1 Repeat-ability1 Standard Outputs2 Power Required3 Pressure Rating  Pressure Sens.4 Temp Rating5. Temp.Sens.1 NIST Cert. Viscosity(Max)
50K sensor 1.5% 0.5% VDC 12VDC,100 mA 150 psi .02%/psi 5-50C 0.15%/C opt. n/a
50D meter 1.5% 0.5% VDC 12VDC,100 mA 150 psi .02%/psi 5-50C 0.15%/C n/a
80 controller 1.5% 0.5% VDC 12VDC,250 mA 150 psi .02%/psi 5-50C 0.15%/C opt. n/a
80D controller 1.5% 0.5% VDC  12VDC,250 mA 150 psi .02%/psi 5-50C 0.15%/C n/a

BRASS (gas)

Unit Function Accuracy/ Linearity1 Repeat-ability1 Standard Outputs2 Power Required3 Pressure Rating  Pressure Sens.4 Temp Rating5 Temp.Sens.1 NIST Cert Viscosity(Max)
S-113 meter 3.0% 0.5% VDC 12VDC,35 mA 40 psi .07% .5-50C 0.2%/C .opt n/a.

RYTON (gas)

Unit Function Accuracy/ Linearity1 Repeat-ability1 Standard Outputs2 Power Required3 Pressure Rating  Pressure Sens.4 Temp Rating5 Temp.Sens.1 NIST Cert Viscosity(Max)
100 sensor 3.0% 0.5% VDC 12VDC,30 mA 40 psi .07% 5-50C 0.2%/C opt. n/a
110  meter  3.0% 0.5% VDC  115/230 VAC 40 psi .07% 5-50C 0.2%/C opt. n/a
S-110 meter  3.0% 0.5% VDC 12VDC,35 mA 40 psi .07% 5-50C  0.2%/C opt. n/a

STAINLESS (gas)

Unit Function Accuracy/ Linearity1 Repeat-ability1 Standard Outputs2 Power Required3 Pressure Rating  Pressure Sens.4 Temp Rating5 Temp.Sens.1 NIST Cert Viscosity(Max)
50S sensor 1.5% 0.5% VDC 12VDC,100 mA 500 psi .02%/psi 5-50C 0.15%/C opt. n/a
50SD meter 1.5% 0.5% VDC 12VDC,100 mA 500 psi .02%/psi 5-50C 0.15%/C n/a

BRASS (liquid)

Unit Function Accuracy/ Linearity1 Repeat-ability1 Standard Outputs2 Power Required3 Pressure Rating  Pressure Sens.4 Temp Rating5 Temp.Sens.1 NIST Cert Viscosity(Max)
102 sensor 3.0% 0.2% VDC 12VDC,30 mA 500 psi none 5-50C 0.2%/C .opt. 10 cs
102P  sensor 1.0% 0.2% VDC 12VDC,30 mA 500 psi none 5-50C 0.2%/C 10 cs
102T sensor 3.0% 0.2% VDC,HZ 12VDC,35 mA 500 psi none 5-50C 0.2%/C opt. 10 cs
102TP sensor  1.0% 0.2% VDC,HZ 12VDC,35 mA 500 psi none 5-50C 0.2%/C 10 cs
S-112 meter 3.0% 0.2% VDC  12VDC,35 mA 500 psi  none 5-50C 0.2%/C opt. 10 cs
S-112P meter 1.0% 0.2% VDC 12VDC,35 mA 500 psi none 5-50C 0.2%/C 10 cs
G102 sensor 0.5% 0.2% VDC,HZ 12VDC,35 mA 500 psi none  5-50C 0.2%/C 10 cs
G112 meter 0.5% 0.2% VDC 12VDC,35 mA 500 psi  none 5-50C 0.2%/C 10 cs

RYTON (liquid)  

Unit Function Accuracy/ Linearity1 Repeat-ability1 Standard Outputs2 Power Required3 Pressure Rating  Pressure Sens.4 Temp Rating5 Temp.Sens.1 NIST Cert Viscosity(Max)
101 sensor 3.0% 0.2% VDC 12VDC,30 mA 100 psi none 5-50C 0.2%/C opt. 10 cs
101P  sensor  1.0% 0.2% VDC 12VDC,30 mA 100 psi none 5-50C 0.2%/C 10 cs
101T sensor 3.0% 0.2% VDC,HZ 12VDC,35 mA 100 psi none 5-50C 0.2%/C opt. 10 cs
101TP  sensor 1.0% 0.2% VDC,HZ 12VDC,35 mA 100 psi none 5-50C 0.2%/C 10 cs
111 meter 3.0% 0.2% VDC 115/230VAC 100 psi none 5-50C 0.2%/C opt. 10 cs
111P meter 1.0% 0.2% VDC 115/230VAC 100 psi  none 5-50C 0.2%/C 10 cs
S-111 meter 3.0% 0.2% VDC 12VDC,35 mA 100 psi none 5-50C 0.2%/C opt. 10 cs
S-111P  meter 1.0% 0.2% VDC 12VDC,35 mA 100 psi  none 5-50C 0.2%/C 10 cs
G101 sensor 0.5% 0.2% VDC,HZ 12VDC,35 mA 100 psi none 5-50C 0.2%/C 10 cs
G111 meter 0.5% 0.2% VDC 12VDC,35 mA 100 psi none 5-50C 0.2%/C 10 cs
400/
470
controller 2.0% 0.2% none 115/230VAC 100 psi none 5-50C 0.2%/C 10 cs

PTFE (liquid)

Unit Function Accuracy/ Linearity1 Repeat-ability1 Standard Outputs2 Power Required3 Pressure Rating  Pressure Sens.4 Temp Rating5 Temp.Sens.1 NIST Cert Viscosity(Max)
105 sensor 3.0% 0.2% VDC,HZ 12VDC,30 mA  60 psi  none 5-50C 0.2%/C opt.  10 cs
106, no MSB sensor 3.0% 0.2% HZ 12VDC,50 mA 60 psi none 5-50C 0.2%/C opt. 10 cs
106 with MSB-1 sensor 3.0% 0.2%  HZ 24VDC,50 mA  60 psi none 5-50C 0.2%/C opt. 10 cs
106 with MSB-2  sensor 1.0% 0.2% VDC 24VDC,50 mA 60 psi none 5-50C 0.2%/C opt.  10 cs
106 with MSB-3  sensor 1.0% 0.2% 4-20 24VDC,75 mA 60 psi none 5-50C 0.2%/C opt. 10 cs
106 with MSB-4  sensor 3.0% 0.2% HZ 24VDC,50 mA 60 psi none 5-50C 0.2%/C opt. 10 cs
106 with MSB-5 sensor  1.0% 0.2% 4-20 24VDC,75 mA 60 psi none 5-50C 0.2%/C opt. 10 cs
106F sensor 1.0% 0.2% VDC,HZ,
MA
24VDC,75 mA 60 psi none 5-50C 0.2%/C opt. 10 cs
401 controller 2.0% 0.25% 4-20 24VDC,800 mA 60 psi none 5-50C 0.2%/C opt. 10 cs

Footnotes:
1  In percent of Full Scale (specification applies from 20-100% of Full Scale)   
2  VDC=0-5 VDC linear analog output, HZ=Pulse Output, 4-20=4-20 mA linear analog output
3  Current draw listed is maximum.  Typical current draw may be less.
4  Unless indicated, in percent per millimeter of Mercury (mm Hg)   
5 Medium (fluid or gas) temperature may exceed these ratings; call for details.     

All specifications subject to change without notice.

Ryton - Reg TM Phillips 66 Petroleum Co.